Mar 25, 2015 How about using the MIB file from the 3PAR admin tools CD. Convert the MIB to a OIDLIB using Paesslers MIB converter. In PRTG, you will add an SNMP Library sensor and use the new OIDLIB file. Check for new CLI and management console from FTP supplied by HP or software depot. Check compatibility in SPOCK; Plus if you use any other 3Par software such as Recovery manager VSS provider etc check in the release notes for the latest version and then download via supplied FTP link from HP or from the software depot. 3PAR CLI commands via SSH protocol, no need any HPE SW installation, just exachange ssh keys and that's it; Using 3PAR CLI calls, it is necessary for 3PAR storage with firmware 3.2.2 MU4 and higher. Do all actions below under stor2rrd account (lpar2rrd on the Virtual Appliance) unless is explicitly specified root in the. It covers configuring for high availability as well as for the HPE 3PAR OS software suite. Following recommended best. 201 MiB = 2 bytes = 1,048,576 bytes. 301 GiB = 2 bytes = 1,024 MiB = 1,073,741,824 bytes. 1 TiB = 2 40. Home Software and Documents. Software and Documents. Search files. Advanced Search. Click a filter or type in a query to begin your search.
3par Mib Downloads Windows 7
* RECOMMENDED * HPE Offline Bundle for ESXi 6.5 By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Type: | Software - System Management | Version: | 3.6.0(5 Oct 2020) | Operating System(s): | VMware vSphere 6.5 | File name: | esxi6.5uX-mgmt-bundle-3.6.0-9.zip (15 MB) |
The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries. Agentless Management Service Added the option to enable/disable AHS Logical Disk Usage logging To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: 55bcdc680d52ad56d9428249eb6a702ba873ec94848ad096ea5712020ed3e54d | esxi6.5uX-mgmt-bundle-3.6.0-9.zip |
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained. Installation:
Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles. Prerequisites Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide. Procedure - Power off any virtual machines that are running on the host and place the host into maintenance mode.
- Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
- Install the bundle on the ESXi host.
- Install remotely from client, with offline bundle contents on a online depot:
esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml> - Install remotely from client, with offline bundle on ESXi host:
esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip> - Install from ESXi host, with offline bundle on ESXi host:
esxcli software vib install -d <ESXi local path><bundle.zip>
- After the bundle is installed, reboot the ESXi host for the updates to take effect.
- (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
esxcli -s <server> -u root -p mypassword software vib list - (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>
Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide. End User License Agreements: HPE Software License Agreement v1 Eclipse License Libcurl End User License Agreement Net-SNMP License SNIA License zlib End User License Agreement Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Notes:
The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License. A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/ Supported Devices and Features:
VMware vSphere version support: - VMware vSphere 6.5 U2
- VMware vSphere 6.5 U3
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
- Fix duplicate IP address reporting issue
- Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
- Disable Logical Disk Usage logging by default
Version:3.6.0 (5 Oct 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
- Fix duplicate IP address reporting issue
- Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
- Disable Logical Disk Usage logging by default
Agentless Management Service Added the option to enable/disable AHS Logical Disk Usage logging Version:3.5.0 (17 Jan 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
- Fix memory leak issues causing ESXi host to become unresponsive or crash
Agentless Management Service - Fix buffer overrun when acquiring vib summary from ESXi host database
- Fix cpqSePciSlotBoardName for empty slots with no CPU
- Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
- Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
- Fix AMS hang when total IPv6 address string sizes exceed 256 bytes
Version:3.4.5 (16 Sep 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
- Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes
Agentless Management Service - Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Version:3.4.0 (2 Apr 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider
Agentless Management Service - Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Agentless Management Service - Added support for cpqiscsi MIB
- Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log
Version:3.3.6 (29 Nov 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
- Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.
Version:3.3.0 (27 Jun 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed issue with Smart Array Provider reporting change of battery status frequently
Agentless Management Service - Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
- Fixed memory leak partly caused by AMS running in the OS init resource group
- Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
WBEM Providers - Added support for Smart Array Controller model P408i-sb
Agentless Management Service - Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log
Version:3.2.0 (21 Mar 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
- Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
- Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
- Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
- Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.
Agentless Management Service - Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system
Agentless Management Service - Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
- Added support for HPE Smart Array P824i-p MR controller
- Added support for reporting multiple IPV6 addresses configured for Ethernet ports
- Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
- Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
Version:3.1.5 (9 Nov 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. HPE Insight Management WBEM Providers: HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5 This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information. HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5 This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller. HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts. Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us. HPE Agentless Management Service: - Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
- Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.
Added HPE Insight Management WBEM Provider support for new FCHBA. Version:3.1.1 (28 Jul 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5 Version:3.1.0 (12 Jul 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. AMS fixes: - Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
- Fixed AMS crash when multiple NICs of the same driver are installed
WBEM Provider features: - Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
- Added support for smartpqi driver and Gen10 Smart Array controllers.
- Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
- Added Firmware update audit logging support to Smart Component Installer provider
AMS features: - Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
- Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor
The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh. Version:2.6.2 (15 May 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Version:2.6.0 (18 Nov 2016) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Provider Features: - Added support for Native Interface in Ethernet Port Provider
- Added support for Native interface in Smart Array Provider
AMS features: - Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives
Type: | Software - System Management | Version: | 3.6.0(5 Oct 2020) | Operating System(s): | |
DescriptionThe HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries. EnhancementsAgentless Management Service Added the option to enable/disable AHS Logical Disk Usage logging Installation InstructionsTo ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: 55bcdc680d52ad56d9428249eb6a702ba873ec94848ad096ea5712020ed3e54d | esxi6.5uX-mgmt-bundle-3.6.0-9.zip |
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained. Installation:
Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles. Prerequisites Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide. Procedure - Power off any virtual machines that are running on the host and place the host into maintenance mode.
- Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
- Install the bundle on the ESXi host.
- Install remotely from client, with offline bundle contents on a online depot:
esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml> - Install remotely from client, with offline bundle on ESXi host:
esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip> - Install from ESXi host, with offline bundle on ESXi host:
esxcli software vib install -d <ESXi local path><bundle.zip>
- After the bundle is installed, reboot the ESXi host for the updates to take effect.
- (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
esxcli -s <server> -u root -p mypassword software vib list - (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>
Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager Windows xp sp3 iso bootable free. The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide. Release NotesEnd User License Agreements: HPE Software License Agreement v1 Eclipse License Libcurl End User License Agreement Net-SNMP License SNIA License zlib End User License Agreement Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Notes:
The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License. A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/ Supported Devices and Features:
VMware vSphere version support: - VMware vSphere 6.5 U2
- VMware vSphere 6.5 U3
FixesUpgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
- Fix duplicate IP address reporting issue
- Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
- Disable Logical Disk Usage logging by default
Revision HistoryVersion:3.6.0 (5 Oct 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
- Fix duplicate IP address reporting issue
- Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
- Disable Logical Disk Usage logging by default
Agentless Management Service Added the option to enable/disable AHS Logical Disk Usage logging Version:3.5.0 (17 Jan 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
- Fix memory leak issues causing ESXi host to become unresponsive or crash
Agentless Management Service - Fix buffer overrun when acquiring vib summary from ESXi host database
- Fix cpqSePciSlotBoardName for empty slots with no CPU
- Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
- Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
- Fix AMS hang when total IPv6 address string sizes exceed 256 bytes
Version:3.4.5 (16 Sep 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
- Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes
Agentless Management Service - Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Version:3.4.0 (2 Apr 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider
Agentless Management Service - Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Agentless Management Service - Added support for cpqiscsi MIB
- Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log
Version:3.3.6 (29 Nov 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
- Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.
Version:3.3.0 (27 Jun 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed issue with Smart Array Provider reporting change of battery status frequently
Agentless Management Service - Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
- Fixed memory leak partly caused by AMS running in the OS init resource group
- Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
WBEM Providers - Added support for Smart Array Controller model P408i-sb
Agentless Management Service - Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log
Version:3.2.0 (21 Mar 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
- Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
- Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
- Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
- Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.
Agentless Management Service - Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system
Agentless Management Service - Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
- Added support for HPE Smart Array P824i-p MR controller
- Added support for reporting multiple IPV6 addresses configured for Ethernet ports
- Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
- Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
Version:3.1.5 (9 Nov 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. HPE Insight Management WBEM Providers: HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5 This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information. HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5 This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller. HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts. Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us. HPE Agentless Management Service: - Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
- Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.
Added HPE Insight Management WBEM Provider support for new FCHBA. Version:3.1.1 (28 Jul 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5 Version:3.1.0 (12 Jul 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. AMS fixes: - Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
- Fixed AMS crash when multiple NICs of the same driver are installed
WBEM Provider features: - Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
- Added support for smartpqi driver and Gen10 Smart Array controllers.
- Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
- Added Firmware update audit logging support to Smart Component Installer provider
AMS features: - Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
- Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor
The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh. Version:2.6.2 (15 May 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Version:2.6.0 (18 Nov 2016) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Provider Features: - Added support for Native Interface in Ethernet Port Provider
- Added support for Native interface in Smart Array Provider
AMS features: - Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives
|
|
3par Mib Downloads Download
Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models. |
|